The power of the press is small. What should I do

What should I do if the power of the press is small? The hydraulic cylinder has been used for a long time, the parts are loose, the hydraulic cylinder is leaking, the leakage in the original parts is large, and the pump pressure is small. The system pressure is too high. When the system does not require pressure oil, the oil still overflows back to the oil tank under the set pressure of the overflow valve. That is, the unloading circuit has poor action, the accumulator capacity is insufficient or defective, the oil is dirty or the oil supply is insufficient, and the oil viscosity is not correct: the water supply fails or the electric fan fails, the cooling water pipe has deposits or scales, and the cooling area of the oil tank is insufficient.

The pump, motor, valve, cylinder and other components are worn, and the resistance of oil is too large. For example, the inner diameter of the pipeline is not compatible with the required flow. Perhaps the valve standard is too small, the energy loss is too large, and there is a heat source nearby. The radiation heat is large. Solution: under the condition of satisfying the operation requirements, try to reduce the pressure to the appropriate pressure and improve the unloading circuit planning;

Check the electric control circuit and corresponding valve action; Lower the unloading pressure; In case of high-pressure small flow and low-pressure large flow, select variable displacement pump, replace large accumulator, repair accumulator, clean or replace oil filter; Add oil to the regular oil level, replace the oil with suitable viscosity, check the cooling water system, replace and repair the solenoid water valve;

Replace and repair electric fans, clean, repair or replace coolers, modify the cooling system or increase the capacity of the oil tank, replace worn components, pipes and valves with appropriate dimensions of the equipment, select reflective plates of thermal insulation materials or change the location; Set ventilation and cooling equipment. Select appropriate operating oil.

The low pressure of the hydraulic pipe locking machine may be caused by improper regulation of the overflow valve. It can regulate the overflow valve to improve the system pressure, which has nothing to do with the rotation speed. The rotation speed of the motor affects the flow of your pump and does not affect your system pressure.


WECHAT
©copyrightNingbo runke Hydraulic Equipment Co., Ltd 备案号:浙ICP备2022020277号-1
About the website limit word invalidation agreement: This website fully supports the relevant provisions on "limited prohibited words" implemented by the "Advertising Law of the People's Republic of China", and has tried its best to avoid the use of "prohibited words". Therefore, from now on, any page of this website that contains text or pictures that limit the introduction of "prohibited words" is not the subjective will of this website and will be invalid immediately, and cannot be used as a reference for any customer behavior. All visitors to this website agree to this agreement! Thanks for your cooperation!